{"id":6935659872415,"title":"PAL-Salt Mohr Digital Refractometer","handle":"pal-salt-mohr-digital-refractometer","description":"\u003cspan data-sheets-formula-bar-text-style=\"font-size:15px;color:#000000;font-weight:normal;text-decoration:none;font-family:'docs-Lato';font-style:normal;text-decoration-skip-ink:none;\" data-mce-fragment=\"1\"\u003e\u003cspan data-sheets-formula-bar-text-style=\"font-size:15px;color:#000000;font-weight:normal;text-decoration:none;font-family:'docs-Lato';font-style:normal;text-decoration-skip-ink:none;\" data-mce-fragment=\"1\"\u003ePAL-SALT Mohr gives a reading similar to those obtained from the Mohr’s method (titration). Like other ATAGO salt meters, PAL-SALT Mohr utilizes conductivity to measure samples. This unit also features an offset function which allows for readings to be compensated based on known standards.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003ePAL-SALT Mohr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCat.No.\u003c\/th\u003e\n\u003ctd\u003e4251\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eScale\u003c\/th\u003e\n\u003ctd\u003eSalt concentration (g\/100mL) \u003cbr\u003eTemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMethod\u003c\/th\u003e\n\u003ctd\u003eConductivity method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003ctd\u003e0.00 to 10.0% (g\/100mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.01% for salt concentration of 0.00 to 2.99%\u003cbr\u003e0.1% for salt concentration of 3.0 to 10.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003eDisplayed value ±0.05%\u003cbr\u003e(for salt concentration of 0.00 to 0.99%)\u003cbr\u003eRelative precision ±5%\u003cbr\u003e(for salt concentration of 1.00 to 10.0%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample temp.\u003c\/th\u003e\n\u003ctd\u003e5~100℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2021-07-12T14:52:14+02:00","created_at":"2021-07-12T14:52:14+02:00","vendor":"Monitoring and Control Laboratories","type":"Agriculture","tags":["atago salt tester","digital salt tester","NaCl tester","PAL-Salt Meter","portable salinity tester","salinity refractometer","salt meter for solid samples","salt meters","Salt refractometer","waterproof salt tester"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":40534349217951,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"PAL-Salt Mohr Digital Refractometer","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/selectech.co.za\/cdn\/shop\/products\/SALT-METER-PAL-SALT-Mohr.jpg?v=1626094657"],"featured_image":"\/\/selectech.co.za\/cdn\/shop\/products\/SALT-METER-PAL-SALT-Mohr.jpg?v=1626094657","options":["Title"],"media":[{"alt":null,"id":22282143957151,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/selectech.co.za\/cdn\/shop\/products\/SALT-METER-PAL-SALT-Mohr.jpg?v=1626094657"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/selectech.co.za\/cdn\/shop\/products\/SALT-METER-PAL-SALT-Mohr.jpg?v=1626094657","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cspan data-sheets-formula-bar-text-style=\"font-size:15px;color:#000000;font-weight:normal;text-decoration:none;font-family:'docs-Lato';font-style:normal;text-decoration-skip-ink:none;\" data-mce-fragment=\"1\"\u003e\u003cspan data-sheets-formula-bar-text-style=\"font-size:15px;color:#000000;font-weight:normal;text-decoration:none;font-family:'docs-Lato';font-style:normal;text-decoration-skip-ink:none;\" data-mce-fragment=\"1\"\u003ePAL-SALT Mohr gives a reading similar to those obtained from the Mohr’s method (titration). Like other ATAGO salt meters, PAL-SALT Mohr utilizes conductivity to measure samples. This unit also features an offset function which allows for readings to be compensated based on known standards.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003ePAL-SALT Mohr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCat.No.\u003c\/th\u003e\n\u003ctd\u003e4251\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eScale\u003c\/th\u003e\n\u003ctd\u003eSalt concentration (g\/100mL) \u003cbr\u003eTemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMethod\u003c\/th\u003e\n\u003ctd\u003eConductivity method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003ctd\u003e0.00 to 10.0% (g\/100mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e0.01% for salt concentration of 0.00 to 2.99%\u003cbr\u003e0.1% for salt concentration of 3.0 to 10.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003eDisplayed value ±0.05%\u003cbr\u003e(for salt concentration of 0.00 to 0.99%)\u003cbr\u003eRelative precision ±5%\u003cbr\u003e(for salt concentration of 1.00 to 10.0%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample temp.\u003c\/th\u003e\n\u003ctd\u003e5~100℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

PAL-Salt Mohr Digital Refractometer

Product Description
PAL-SALT Mohr gives a reading similar to those obtained from the Mohr’s method (titration). Like other ATAGO salt meters, PAL-SALT Mohr utilizes conductivity to measure samples. This unit also features an offset function which allows for readings to be compensated based on known standards.

Model PAL-SALT Mohr
Cat.No. 4251
Scale Salt concentration (g/100mL)
Temperature
Method Conductivity method
Range 0.00 to 10.0% (g/100mL)
Resolution 0.01% for salt concentration of 0.00 to 2.99%
0.1% for salt concentration of 3.0 to 10.0%
Accuracy Displayed value ±0.05%
(for salt concentration of 0.00 to 0.99%)
Relative precision ±5%
(for salt concentration of 1.00 to 10.0%)
Sample temp. 5~100℃
.
Maximum quantity available reached.