{"id":7557584978079,"title":"Lovibond SD 400 Oxi L","handle":"lovibond-sd-400-oxi-l","description":"\u003ch2 class=\"c-title c-title--secondary u-text-appearance-h5 u-color-black\"\u003e\u003cspan class=\"o-layout\"\u003e\u003cspan class=\"o-layout__item u-7\/12@medium\"\u003eOptical determination of dissolved oxygen - precise and fast measurement results \u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\" class=\"u-text-appearance-h2 u-color-blue u-margin-top-tiny u-margin-bottom-tiny\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\" class=\"ezxmltext-field c-list-default\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLuminescence technology\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHigh accuracy\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLow maintenace\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrift-free, optical measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\" class=\"ezxmltext-field c-list-default u-margin-bottom-small\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe portable SD 400 Oxi L handheld meter allows the determination of dissolved oxygen using the highly accurate optical luminescence technology. The advantages of optical oxygen determination over conventional methods are manifold:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNo need of an internal electrolyte: no additional effort, no hidden costs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNo sample flow necessary for stable sensor response\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNo interferences from other gases\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrift-free measurement ensures extremely precise results\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLow wear and low maintenance due to a long-life membrane head\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReady for immediate use without warm-up or polarisation times\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFunctions such as the automatic temperature, pressure and salt compensation are ideal to match individual measuring conditions and make the instrument the perfect all-rounder in water analysis. Calibration data are sensor-specific and stored on the integrated SD card in the unit, which also contains a free software for monitoring, storing and transferring measurement data.\u003c\/p\u003e\n\u003csection role=\"tabpanel\" class=\"c-tabs__panel u-padding-small\"\u003e\n\u003cdiv class=\"ezxmltext-field c-list-default\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eModern technology\u003c\/b\u003e \u003cbr\u003eThe SD 400 Oxi L uses optical luminescence technology. Your advantage: High measuring accuracy, fast response and absolutely user-friendly measuring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLow maintenance\u003c\/b\u003e \u003cbr\u003eThanks to luminescence technology, no electrolyte is needed. Regular refilling is therefore no longer necessary - and maintenance is reduced to a minimum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eData management\u003c\/b\u003e \u003cbr\u003eBy means of integrated software (\"data logger\") the collection and analysis of data is simplified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSuitable for \"dilution BOD\" determination\u003c\/b\u003e \u003cbr\u003eThe electrode of the SD 400 Oxi L is optimized for standard BOD bottles (NS 19\/26). The device is therefore ideally suited for standard-compliant BOD determination of the dilution BOD.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","published_at":"2022-10-23T13:42:53+02:00","created_at":"2022-10-23T13:35:41+02:00","vendor":"Lovibond","type":"Electro Chemistry","tags":["740030","dissolved oxygen meter","dissolved oxygen water","DO meter","Electro chemistry","handheld water oxygen meter","lovibond DO meter","Oxi L","Oxi meter","oxygen determination in water","SD 400","SD400","water testing"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":42726009208991,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Lovibond SD 400 Oxi L","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-3.jpg?v=1666525101","\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-2.jpg?v=1666525101","\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-1.jpg?v=1666525101","\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-6.jpg?v=1666525101","\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-5.jpg?v=1666525101","\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-4.jpg?v=1666525101"],"featured_image":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-3.jpg?v=1666525101","options":["Title"],"media":[{"alt":null,"id":26837486665887,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-3.jpg?v=1666525101"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-3.jpg?v=1666525101","width":1200},{"alt":null,"id":26837486698655,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-2.jpg?v=1666525101"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-2.jpg?v=1666525101","width":1200},{"alt":null,"id":26837486731423,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-1.jpg?v=1666525101"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-1.jpg?v=1666525101","width":1200},{"alt":null,"id":26837486567583,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-6.jpg?v=1666525101"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-6.jpg?v=1666525101","width":1200},{"alt":null,"id":26837486600351,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-5.jpg?v=1666525101"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-5.jpg?v=1666525101","width":1200},{"alt":null,"id":26837486633119,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-4.jpg?v=1666525101"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/selectech.co.za\/cdn\/shop\/products\/LovibondSD400OxiL-4.jpg?v=1666525101","width":1200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2 class=\"c-title c-title--secondary u-text-appearance-h5 u-color-black\"\u003e\u003cspan class=\"o-layout\"\u003e\u003cspan class=\"o-layout__item u-7\/12@medium\"\u003eOptical determination of dissolved oxygen - precise and fast measurement results \u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\" class=\"u-text-appearance-h2 u-color-blue u-margin-top-tiny u-margin-bottom-tiny\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\" class=\"ezxmltext-field c-list-default\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLuminescence technology\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHigh accuracy\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLow maintenace\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrift-free, optical measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\" class=\"ezxmltext-field c-list-default u-margin-bottom-small\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe portable SD 400 Oxi L handheld meter allows the determination of dissolved oxygen using the highly accurate optical luminescence technology. The advantages of optical oxygen determination over conventional methods are manifold:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNo need of an internal electrolyte: no additional effort, no hidden costs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNo sample flow necessary for stable sensor response\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNo interferences from other gases\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDrift-free measurement ensures extremely precise results\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLow wear and low maintenance due to a long-life membrane head\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReady for immediate use without warm-up or polarisation times\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFunctions such as the automatic temperature, pressure and salt compensation are ideal to match individual measuring conditions and make the instrument the perfect all-rounder in water analysis. Calibration data are sensor-specific and stored on the integrated SD card in the unit, which also contains a free software for monitoring, storing and transferring measurement data.\u003c\/p\u003e\n\u003csection role=\"tabpanel\" class=\"c-tabs__panel u-padding-small\"\u003e\n\u003cdiv class=\"ezxmltext-field c-list-default\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eModern technology\u003c\/b\u003e \u003cbr\u003eThe SD 400 Oxi L uses optical luminescence technology. Your advantage: High measuring accuracy, fast response and absolutely user-friendly measuring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLow maintenance\u003c\/b\u003e \u003cbr\u003eThanks to luminescence technology, no electrolyte is needed. Regular refilling is therefore no longer necessary - and maintenance is reduced to a minimum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eData management\u003c\/b\u003e \u003cbr\u003eBy means of integrated software (\"data logger\") the collection and analysis of data is simplified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSuitable for \"dilution BOD\" determination\u003c\/b\u003e \u003cbr\u003eThe electrode of the SD 400 Oxi L is optimized for standard BOD bottles (NS 19\/26). The device is therefore ideally suited for standard-compliant BOD determination of the dilution BOD.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e"}

Lovibond SD 400 Oxi L

Product Description

Optical determination of dissolved oxygen - precise and fast measurement results

Highlights

  • Luminescence technology
  • High accuracy
  • Low maintenace
  • Drift-free, optical measurement

The portable SD 400 Oxi L handheld meter allows the determination of dissolved oxygen using the highly accurate optical luminescence technology. The advantages of optical oxygen determination over conventional methods are manifold:

  • No need of an internal electrolyte: no additional effort, no hidden costs
  • No sample flow necessary for stable sensor response
  • No interferences from other gases
  • Drift-free measurement ensures extremely precise results
  • Low wear and low maintenance due to a long-life membrane head
  • Ready for immediate use without warm-up or polarisation times

Functions such as the automatic temperature, pressure and salt compensation are ideal to match individual measuring conditions and make the instrument the perfect all-rounder in water analysis. Calibration data are sensor-specific and stored on the integrated SD card in the unit, which also contains a free software for monitoring, storing and transferring measurement data.

  • Modern technology
    The SD 400 Oxi L uses optical luminescence technology. Your advantage: High measuring accuracy, fast response and absolutely user-friendly measuring.
  • Low maintenance
    Thanks to luminescence technology, no electrolyte is needed. Regular refilling is therefore no longer necessary - and maintenance is reduced to a minimum.
  • Data management
    By means of integrated software ("data logger") the collection and analysis of data is simplified.
  • Suitable for "dilution BOD" determination
    The electrode of the SD 400 Oxi L is optimized for standard BOD bottles (NS 19/26). The device is therefore ideally suited for standard-compliant BOD determination of the dilution BOD.
.