{"id":6002037096607,"title":"Hygiena™ InSite Listeria","handle":"hygiena™-insite-listeria","description":"\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eEnvironmental\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eTest\u003c\/h3\u003e\n\u003cp\u003eHygiena™ InSite\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis an easy-to-use, self-contained, environmental\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003etest. Each device contains a chromogenic liquid media formulated with antibiotics, growth enhancers, and color-changing compounds specific to\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e. Simply swab the test area and wait. A change in color after 24-48 hours of incubation is considered presumptive positive. No expensive lab equipment is required and no additional sample handling of the sample is necessary.\u003c\/p\u003e\n\u003ch3\u003eTest in-house, save valuable time.\u003c\/h3\u003e\n\u003cp\u003eInSite\u003cspan\u003e \u003c\/span\u003e\u003ci\u003eListeria \u003c\/i\u003ecomplements your lab testing with quick on-site screening results in just 24-48 hours. Eliminate the lengthy wait time for outside lab results and get ahead of contamination issues.\u003c\/p\u003e\n\u003ch3\u003eEasy-to-interpret color results.\u003c\/h3\u003e\n\u003cp\u003eIt doesn't take a microbiologist to understand these results. When\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis present in a sample, the liquid media changes color from amber to black. \u003c\/p\u003e\n\u003ch3\u003eNo more unnecessary work. \u003c\/h3\u003e\n\u003cp\u003eCut back on labor and materials. This all-in-one test utilizes a large foam sampler for maximum sample collection that eliminates the need for additional sponges, diluents, bags, and pipettes. The only equipment you'll need is an incubator. \u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eBenefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDelivers results in 24-48 hours\u003c\/li\u003e\n\u003cli\u003eCost-effective test\u003c\/li\u003e\n\u003cli\u003eSelf-contained reagent- no transfers minimizing the chance of contamination\u003c\/li\u003e\n\u003cli\u003eColor-changing device is easy to interpret\u003c\/li\u003e\n\u003cli\u003eOnly equipment required is a 37°C ± 1° incubator - reduces materials and labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap-Valve™ technology - snap \u0026amp; squeeze\u003c\/li\u003e\n\u003cli\u003eLarge 2.5-inch foam swab for maximum sample pickup\u003c\/li\u003e\n\u003cli\u003eWrite-on swab label for easy sample identification\u003c\/li\u003e\n\u003cli\u003ePresumptive positive results are available for the most common\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria spp\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ein as little as 30 hours at levels as low as 1-10 CFU\/mL\n\u003cul\u003e\n\u003cli\u003ePresumptive positive samples should be confirmed by streaking sample onto commonly used selective\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eagar plates such as Modified Oxford agar, Palcam agar, or any other recognized confirmatory procedure. Typical\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ecolonies on selective agar plates could then be further analyzed by more definitive tests such as microscopy, biochemical tests, etc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompared to UVM and BLEB, provides superior\/equivalent recovery and faster detection of as low as 10-50 heat injured\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria monocytogenes\u003c\/em\u003e\/mL within ~24-30 hours of incubation.\u003c\/li\u003e\n\u003cli\u003eProvides higher level of selectivity and sensitivity for heat injured\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eL. monocytogene\u003c\/em\u003es under binary competition conditions compared to BLEB and UVM media\u003c\/li\u003e\n\u003cli\u003e12 month shelf life at refrigerated temperatures (2 - 8 °C)\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2020-12-15T15:53:11+02:00","created_at":"2020-12-15T15:53:10+02:00","vendor":"Hygenia","type":"Food, Beverage and Packaging","tags":["Angola","Botswana","Cape Town","DRC","Durban","Ethiopia","Gauteng","Hygiene \u0026 Bacteria","Joburg","Johannesburg","Listeria","Listeria species test","Madagascar","Mozambique","Namibia","Pretoria","Tanzania","Test Kit","Uganda","Zambia","Zimbabwe"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37288479096991,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Hygiena™ InSite Listeria","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0450\/0992\/8351\/products\/Hygiena_InSiteListeria.png?v=1610381256"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0450\/0992\/8351\/products\/Hygiena_InSiteListeria.png?v=1610381256","options":["Title"],"media":[{"alt":"Hygiena™ InSite Listeria","id":12983801675935,"position":1,"preview_image":{"aspect_ratio":8.212,"height":236,"width":1938,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0450\/0992\/8351\/products\/Hygiena_InSiteListeria.png?v=1608040392"},"aspect_ratio":8.212,"height":236,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0450\/0992\/8351\/products\/Hygiena_InSiteListeria.png?v=1608040392","width":1938}],"content":"\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eEnvironmental\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eTest\u003c\/h3\u003e\n\u003cp\u003eHygiena™ InSite\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis an easy-to-use, self-contained, environmental\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003etest. Each device contains a chromogenic liquid media formulated with antibiotics, growth enhancers, and color-changing compounds specific to\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e. Simply swab the test area and wait. A change in color after 24-48 hours of incubation is considered presumptive positive. No expensive lab equipment is required and no additional sample handling of the sample is necessary.\u003c\/p\u003e\n\u003ch3\u003eTest in-house, save valuable time.\u003c\/h3\u003e\n\u003cp\u003eInSite\u003cspan\u003e \u003c\/span\u003e\u003ci\u003eListeria \u003c\/i\u003ecomplements your lab testing with quick on-site screening results in just 24-48 hours. Eliminate the lengthy wait time for outside lab results and get ahead of contamination issues.\u003c\/p\u003e\n\u003ch3\u003eEasy-to-interpret color results.\u003c\/h3\u003e\n\u003cp\u003eIt doesn't take a microbiologist to understand these results. When\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis present in a sample, the liquid media changes color from amber to black. \u003c\/p\u003e\n\u003ch3\u003eNo more unnecessary work. \u003c\/h3\u003e\n\u003cp\u003eCut back on labor and materials. This all-in-one test utilizes a large foam sampler for maximum sample collection that eliminates the need for additional sponges, diluents, bags, and pipettes. The only equipment you'll need is an incubator. \u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eBenefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDelivers results in 24-48 hours\u003c\/li\u003e\n\u003cli\u003eCost-effective test\u003c\/li\u003e\n\u003cli\u003eSelf-contained reagent- no transfers minimizing the chance of contamination\u003c\/li\u003e\n\u003cli\u003eColor-changing device is easy to interpret\u003c\/li\u003e\n\u003cli\u003eOnly equipment required is a 37°C ± 1° incubator - reduces materials and labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap-Valve™ technology - snap \u0026amp; squeeze\u003c\/li\u003e\n\u003cli\u003eLarge 2.5-inch foam swab for maximum sample pickup\u003c\/li\u003e\n\u003cli\u003eWrite-on swab label for easy sample identification\u003c\/li\u003e\n\u003cli\u003ePresumptive positive results are available for the most common\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria spp\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ein as little as 30 hours at levels as low as 1-10 CFU\/mL\n\u003cul\u003e\n\u003cli\u003ePresumptive positive samples should be confirmed by streaking sample onto commonly used selective\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eagar plates such as Modified Oxford agar, Palcam agar, or any other recognized confirmatory procedure. Typical\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ecolonies on selective agar plates could then be further analyzed by more definitive tests such as microscopy, biochemical tests, etc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompared to UVM and BLEB, provides superior\/equivalent recovery and faster detection of as low as 10-50 heat injured\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria monocytogenes\u003c\/em\u003e\/mL within ~24-30 hours of incubation.\u003c\/li\u003e\n\u003cli\u003eProvides higher level of selectivity and sensitivity for heat injured\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eL. monocytogene\u003c\/em\u003es under binary competition conditions compared to BLEB and UVM media\u003c\/li\u003e\n\u003cli\u003e12 month shelf life at refrigerated temperatures (2 - 8 °C)\u003c\/li\u003e\n\u003c\/ul\u003e"}

Hygiena™ InSite Listeria

Product Description

Description

Environmental Listeria species Test

Hygiena™ InSite Listeria is an easy-to-use, self-contained, environmental Listeria species test. Each device contains a chromogenic liquid media formulated with antibiotics, growth enhancers, and color-changing compounds specific to Listeria species. Simply swab the test area and wait. A change in color after 24-48 hours of incubation is considered presumptive positive. No expensive lab equipment is required and no additional sample handling of the sample is necessary.

Test in-house, save valuable time.

InSite Listeria complements your lab testing with quick on-site screening results in just 24-48 hours. Eliminate the lengthy wait time for outside lab results and get ahead of contamination issues.

Easy-to-interpret color results.

It doesn't take a microbiologist to understand these results. When Listeria species is present in a sample, the liquid media changes color from amber to black. 

No more unnecessary work. 

Cut back on labor and materials. This all-in-one test utilizes a large foam sampler for maximum sample collection that eliminates the need for additional sponges, diluents, bags, and pipettes. The only equipment you'll need is an incubator. 

Benefits

  • Delivers results in 24-48 hours
  • Cost-effective test
  • Self-contained reagent- no transfers minimizing the chance of contamination
  • Color-changing device is easy to interpret
  • Only equipment required is a 37°C ± 1° incubator - reduces materials and labor

Specifications

  • Snap-Valve™ technology - snap & squeeze
  • Large 2.5-inch foam swab for maximum sample pickup
  • Write-on swab label for easy sample identification
  • Presumptive positive results are available for the most common Listeria spp in as little as 30 hours at levels as low as 1-10 CFU/mL
    • Presumptive positive samples should be confirmed by streaking sample onto commonly used selective Listeria agar plates such as Modified Oxford agar, Palcam agar, or any other recognized confirmatory procedure. Typical Listeria colonies on selective agar plates could then be further analyzed by more definitive tests such as microscopy, biochemical tests, etc.
  • Compared to UVM and BLEB, provides superior/equivalent recovery and faster detection of as low as 10-50 heat injured Listeria monocytogenes/mL within ~24-30 hours of incubation.
  • Provides higher level of selectivity and sensitivity for heat injured L. monocytogenes under binary competition conditions compared to BLEB and UVM media
  • 12 month shelf life at refrigerated temperatures (2 - 8 °C)
Read more
Maximum quantity available reached.

Related products