{"id":6002037096607,"title":"Hygiena™ InSite Listeria","handle":"hygiena™-insite-listeria","description":"\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eEnvironmental\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eTest\u003c\/h3\u003e\n\u003cp\u003eHygiena™ InSite\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis an easy-to-use, self-contained, environmental\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003etest. Each device contains a chromogenic liquid media formulated with antibiotics, growth enhancers, and color-changing compounds specific to\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e. Simply swab the test area and wait. A change in color after 24-48 hours of incubation is considered presumptive positive. No expensive lab equipment is required and no additional sample handling of the sample is necessary.\u003c\/p\u003e\n\u003ch3\u003eTest in-house, save valuable time.\u003c\/h3\u003e\n\u003cp\u003eInSite\u003cspan\u003e \u003c\/span\u003e\u003ci\u003eListeria \u003c\/i\u003ecomplements your lab testing with quick on-site screening results in just 24-48 hours. Eliminate the lengthy wait time for outside lab results and get ahead of contamination issues.\u003c\/p\u003e\n\u003ch3\u003eEasy-to-interpret color results.\u003c\/h3\u003e\n\u003cp\u003eIt doesn't take a microbiologist to understand these results. When\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis present in a sample, the liquid media changes color from amber to black. \u003c\/p\u003e\n\u003ch3\u003eNo more unnecessary work. \u003c\/h3\u003e\n\u003cp\u003eCut back on labor and materials. This all-in-one test utilizes a large foam sampler for maximum sample collection that eliminates the need for additional sponges, diluents, bags, and pipettes. The only equipment you'll need is an incubator. \u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eBenefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDelivers results in 24-48 hours\u003c\/li\u003e\n\u003cli\u003eCost-effective test\u003c\/li\u003e\n\u003cli\u003eSelf-contained reagent- no transfers minimizing the chance of contamination\u003c\/li\u003e\n\u003cli\u003eColor-changing device is easy to interpret\u003c\/li\u003e\n\u003cli\u003eOnly equipment required is a 37°C ± 1° incubator - reduces materials and labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap-Valve™ technology - snap \u0026amp; squeeze\u003c\/li\u003e\n\u003cli\u003eLarge 2.5-inch foam swab for maximum sample pickup\u003c\/li\u003e\n\u003cli\u003eWrite-on swab label for easy sample identification\u003c\/li\u003e\n\u003cli\u003ePresumptive positive results are available for the most common\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria spp\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ein as little as 30 hours at levels as low as 1-10 CFU\/mL\n\u003cul\u003e\n\u003cli\u003ePresumptive positive samples should be confirmed by streaking sample onto commonly used selective\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eagar plates such as Modified Oxford agar, Palcam agar, or any other recognized confirmatory procedure. Typical\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ecolonies on selective agar plates could then be further analyzed by more definitive tests such as microscopy, biochemical tests, etc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompared to UVM and BLEB, provides superior\/equivalent recovery and faster detection of as low as 10-50 heat injured\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria monocytogenes\u003c\/em\u003e\/mL within ~24-30 hours of incubation.\u003c\/li\u003e\n\u003cli\u003eProvides higher level of selectivity and sensitivity for heat injured\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eL. monocytogene\u003c\/em\u003es under binary competition conditions compared to BLEB and UVM media\u003c\/li\u003e\n\u003cli\u003e12 month shelf life at refrigerated temperatures (2 - 8 °C)\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2020-12-15T15:53:11+02:00","created_at":"2020-12-15T15:53:10+02:00","vendor":"Hygenia","type":"Food, Beverage and Packaging","tags":["Angola","Botswana","Cape Town","DRC","Durban","Ethiopia","Gauteng","Hygiene \u0026 Bacteria","Joburg","Johannesburg","Listeria","Listeria species test","Madagascar","Mozambique","Namibia","Pretoria","Tanzania","Test Kit","Uganda","Zambia","Zimbabwe"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37288479096991,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Hygiena™ InSite Listeria","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0450\/0992\/8351\/products\/Hygiena_InSiteListeria.png?v=1610381256"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0450\/0992\/8351\/products\/Hygiena_InSiteListeria.png?v=1610381256","options":["Title"],"media":[{"alt":"Hygiena™ InSite Listeria","id":12983801675935,"position":1,"preview_image":{"aspect_ratio":8.212,"height":236,"width":1938,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0450\/0992\/8351\/products\/Hygiena_InSiteListeria.png?v=1610381256"},"aspect_ratio":8.212,"height":236,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0450\/0992\/8351\/products\/Hygiena_InSiteListeria.png?v=1610381256","width":1938}],"content":"\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eEnvironmental\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eTest\u003c\/h3\u003e\n\u003cp\u003eHygiena™ InSite\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis an easy-to-use, self-contained, environmental\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003etest. Each device contains a chromogenic liquid media formulated with antibiotics, growth enhancers, and color-changing compounds specific to\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e. Simply swab the test area and wait. A change in color after 24-48 hours of incubation is considered presumptive positive. No expensive lab equipment is required and no additional sample handling of the sample is necessary.\u003c\/p\u003e\n\u003ch3\u003eTest in-house, save valuable time.\u003c\/h3\u003e\n\u003cp\u003eInSite\u003cspan\u003e \u003c\/span\u003e\u003ci\u003eListeria \u003c\/i\u003ecomplements your lab testing with quick on-site screening results in just 24-48 hours. Eliminate the lengthy wait time for outside lab results and get ahead of contamination issues.\u003c\/p\u003e\n\u003ch3\u003eEasy-to-interpret color results.\u003c\/h3\u003e\n\u003cp\u003eIt doesn't take a microbiologist to understand these results. When\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria species\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eis present in a sample, the liquid media changes color from amber to black. \u003c\/p\u003e\n\u003ch3\u003eNo more unnecessary work. \u003c\/h3\u003e\n\u003cp\u003eCut back on labor and materials. This all-in-one test utilizes a large foam sampler for maximum sample collection that eliminates the need for additional sponges, diluents, bags, and pipettes. The only equipment you'll need is an incubator. \u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eBenefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDelivers results in 24-48 hours\u003c\/li\u003e\n\u003cli\u003eCost-effective test\u003c\/li\u003e\n\u003cli\u003eSelf-contained reagent- no transfers minimizing the chance of contamination\u003c\/li\u003e\n\u003cli\u003eColor-changing device is easy to interpret\u003c\/li\u003e\n\u003cli\u003eOnly equipment required is a 37°C ± 1° incubator - reduces materials and labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap-Valve™ technology - snap \u0026amp; squeeze\u003c\/li\u003e\n\u003cli\u003eLarge 2.5-inch foam swab for maximum sample pickup\u003c\/li\u003e\n\u003cli\u003eWrite-on swab label for easy sample identification\u003c\/li\u003e\n\u003cli\u003ePresumptive positive results are available for the most common\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria spp\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ein as little as 30 hours at levels as low as 1-10 CFU\/mL\n\u003cul\u003e\n\u003cli\u003ePresumptive positive samples should be confirmed by streaking sample onto commonly used selective\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eagar plates such as Modified Oxford agar, Palcam agar, or any other recognized confirmatory procedure. Typical\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ecolonies on selective agar plates could then be further analyzed by more definitive tests such as microscopy, biochemical tests, etc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompared to UVM and BLEB, provides superior\/equivalent recovery and faster detection of as low as 10-50 heat injured\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eListeria monocytogenes\u003c\/em\u003e\/mL within ~24-30 hours of incubation.\u003c\/li\u003e\n\u003cli\u003eProvides higher level of selectivity and sensitivity for heat injured\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eL. monocytogene\u003c\/em\u003es under binary competition conditions compared to BLEB and UVM media\u003c\/li\u003e\n\u003cli\u003e12 month shelf life at refrigerated temperatures (2 - 8 °C)\u003c\/li\u003e\n\u003c\/ul\u003e"}