{"id":6002049974431,"title":"AquaSnap Free","handle":"aquasnap-free","description":"\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-fragment=\"1\" data-mce-style=\"text-decoration: underline;\"\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eAquaSnap Free measures ATP that is free in solution. The difference between Total and Free ATP provides a measure of microbial contamination in the sample.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eIntroduction to ATP Testing\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eResidues, particularly food or organic residue, contain large amounts of ATP. When left on a surface, residues can harbor and grow bacteria, cause cross-contamination, develop biofilm and many other problems that can compromise product quality.  After cleaning, all sources of ATP should be significantly reduced. When ATP is brought into contact with Hygiena's unique, liquid-stable reagent, light is emitted in direct proportion to the amount of ATP present. The system measures the amount of light generated and provides information on the level of contamination in seconds.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eATP Testing for Water Cleanliness Verification\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAquaSnap Total and Free Water ATP Tests are quick, portable, and easy-to-use. Just collect your sample, activate and place it in your Hygiena instrument for cleanliness results in 15 seconds. The handheld instrument and pen-sized swab device are easily portable and don't require any bulky lab equipment, making AquaSnap the ideal solution for testing water cleanliness abroad.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eQuick CIP sanitation check.\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith AquaSnap Total, sanitation teams can check the cleaning efficiency of CIP systems quickly. Simply sample the water from the last wash of the CIP cycle, activate the swab, and read the results in your Hygiena™ luminometer. If ATP is present in the water, the cleaning cycle is not properly removing residue and the surfaces are still dirty.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eBetter design gives better results.\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe honeycomb shaped dipper tip used with AquaSnap collects exactly 100µl of sample, making sure you are collecting the same amount every time. Other ATP water tests use a swab designed for surface sample collection which causes large sample variation. Surface swabs are pre-moistened with an extractant, so the absorption rate will vary based on how much sample can be absorbed. In addition, extractant will be lost when first dipped into sample. AquaSnap's honey dipper collection tip eliminates these issues providing more accurate results.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eLiquid-stable chemistry.\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAquaSnap contains liquid-stable chemistry in the patented Snap-Valve™ bulb. The unique chemistry and design eliminate the need to reconstitute lyophilized pellets, enabling consistent results. The chemistry in AquaSnap is a high power, ultra-sensitive formulation to deliver precise results for low levels of ATP. AquaSnap's chemistry is robust and resistant to harsh samples or sanitizer effects.\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-fragment=\"1\" data-mce-style=\"text-decoration: underline;\"\u003eBenefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReady-to-use out of box\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEasy-to-use and reduces user variation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePatented design produces repeatable and accurate results\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTolerant to temperature abuse and sanitizers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll-in-one test device with collection dipper tip\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConsistent sample collection (100 µl) over swab or sponge tip test\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLiquid-stable chemistry eliminates the need to reconstitute a pellet, giving more accurate results with less variation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTrue and accurate results at low RLU levels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReliable trending at low ATP and low RLU levels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLow carbon footprint - Recyclable #7\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-fragment=\"1\" data-mce-style=\"text-decoration: underline;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShelf life:\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e15 months at refrigerated temperatures (2-8ºC)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e4 weeks room temperature (21-25ºC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eCompatible Luminometers\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnSURE™ Touch\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnSURE™\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSystemSURE Plus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","published_at":"2020-12-15T16:02:55+02:00","created_at":"2020-12-15T16:02:53+02:00","vendor":"Hygenia","type":"water quality environment","tags":["adenosine triphosphate AQ100. Aquasnap Free","aqua snap swabs","Aquasnap Swabs","ATP Analyzers","ATP in water","ATP measurement in solutions","ATP Measurer","ATP test","ATP testing","carbon footprint","collecting surface sample","free ATP","Hygiena","Hygiena swabs","hygiene swabbing system","Laboratory Equipment","low carbon","luminometer","Non-Microbial ATP","surface sampling","swabbing system","Water tester","water testing"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37288519663775,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AquaSnap Free","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/selectech.co.za\/cdn\/shop\/products\/AquaSnap-Free-Swabs.jpg?v=1664244589"],"featured_image":"\/\/selectech.co.za\/cdn\/shop\/products\/AquaSnap-Free-Swabs.jpg?v=1664244589","options":["Title"],"media":[{"alt":null,"id":26602559307935,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/selectech.co.za\/cdn\/shop\/products\/AquaSnap-Free-Swabs.jpg?v=1664244589"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/selectech.co.za\/cdn\/shop\/products\/AquaSnap-Free-Swabs.jpg?v=1664244589","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-fragment=\"1\" data-mce-style=\"text-decoration: underline;\"\u003eDescription\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan\u003eAquaSnap Free measures ATP that is free in solution. The difference between Total and Free ATP provides a measure of microbial contamination in the sample.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eIntroduction to ATP Testing\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eResidues, particularly food or organic residue, contain large amounts of ATP. When left on a surface, residues can harbor and grow bacteria, cause cross-contamination, develop biofilm and many other problems that can compromise product quality.  After cleaning, all sources of ATP should be significantly reduced. When ATP is brought into contact with Hygiena's unique, liquid-stable reagent, light is emitted in direct proportion to the amount of ATP present. The system measures the amount of light generated and provides information on the level of contamination in seconds.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eATP Testing for Water Cleanliness Verification\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAquaSnap Total and Free Water ATP Tests are quick, portable, and easy-to-use. Just collect your sample, activate and place it in your Hygiena instrument for cleanliness results in 15 seconds. The handheld instrument and pen-sized swab device are easily portable and don't require any bulky lab equipment, making AquaSnap the ideal solution for testing water cleanliness abroad.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eQuick CIP sanitation check.\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith AquaSnap Total, sanitation teams can check the cleaning efficiency of CIP systems quickly. Simply sample the water from the last wash of the CIP cycle, activate the swab, and read the results in your Hygiena™ luminometer. If ATP is present in the water, the cleaning cycle is not properly removing residue and the surfaces are still dirty.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eBetter design gives better results.\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe honeycomb shaped dipper tip used with AquaSnap collects exactly 100µl of sample, making sure you are collecting the same amount every time. Other ATP water tests use a swab designed for surface sample collection which causes large sample variation. Surface swabs are pre-moistened with an extractant, so the absorption rate will vary based on how much sample can be absorbed. In addition, extractant will be lost when first dipped into sample. AquaSnap's honey dipper collection tip eliminates these issues providing more accurate results.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eLiquid-stable chemistry.\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAquaSnap contains liquid-stable chemistry in the patented Snap-Valve™ bulb. The unique chemistry and design eliminate the need to reconstitute lyophilized pellets, enabling consistent results. The chemistry in AquaSnap is a high power, ultra-sensitive formulation to deliver precise results for low levels of ATP. AquaSnap's chemistry is robust and resistant to harsh samples or sanitizer effects.\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-fragment=\"1\" data-mce-style=\"text-decoration: underline;\"\u003eBenefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReady-to-use out of box\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEasy-to-use and reduces user variation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePatented design produces repeatable and accurate results\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTolerant to temperature abuse and sanitizers\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll-in-one test device with collection dipper tip\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eConsistent sample collection (100 µl) over swab or sponge tip test\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLiquid-stable chemistry eliminates the need to reconstitute a pellet, giving more accurate results with less variation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTrue and accurate results at low RLU levels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReliable trending at low ATP and low RLU levels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLow carbon footprint - Recyclable #7\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-fragment=\"1\" data-mce-style=\"text-decoration: underline;\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eShelf life:\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e15 months at refrigerated temperatures (2-8ºC)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e4 weeks room temperature (21-25ºC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eCompatible Luminometers\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnSURE™ Touch\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnSURE™\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSystemSURE Plus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e"}

AquaSnap Free

Product Description

Description

AquaSnap Free measures ATP that is free in solution. The difference between Total and Free ATP provides a measure of microbial contamination in the sample.

Introduction to ATP Testing

Residues, particularly food or organic residue, contain large amounts of ATP. When left on a surface, residues can harbor and grow bacteria, cause cross-contamination, develop biofilm and many other problems that can compromise product quality.  After cleaning, all sources of ATP should be significantly reduced. When ATP is brought into contact with Hygiena's unique, liquid-stable reagent, light is emitted in direct proportion to the amount of ATP present. The system measures the amount of light generated and provides information on the level of contamination in seconds.

ATP Testing for Water Cleanliness Verification

AquaSnap Total and Free Water ATP Tests are quick, portable, and easy-to-use. Just collect your sample, activate and place it in your Hygiena instrument for cleanliness results in 15 seconds. The handheld instrument and pen-sized swab device are easily portable and don't require any bulky lab equipment, making AquaSnap the ideal solution for testing water cleanliness abroad.

Quick CIP sanitation check.

With AquaSnap Total, sanitation teams can check the cleaning efficiency of CIP systems quickly. Simply sample the water from the last wash of the CIP cycle, activate the swab, and read the results in your Hygiena™ luminometer. If ATP is present in the water, the cleaning cycle is not properly removing residue and the surfaces are still dirty.

Better design gives better results.

The honeycomb shaped dipper tip used with AquaSnap collects exactly 100µl of sample, making sure you are collecting the same amount every time. Other ATP water tests use a swab designed for surface sample collection which causes large sample variation. Surface swabs are pre-moistened with an extractant, so the absorption rate will vary based on how much sample can be absorbed. In addition, extractant will be lost when first dipped into sample. AquaSnap's honey dipper collection tip eliminates these issues providing more accurate results.

Liquid-stable chemistry.

AquaSnap contains liquid-stable chemistry in the patented Snap-Valve™ bulb. The unique chemistry and design eliminate the need to reconstitute lyophilized pellets, enabling consistent results. The chemistry in AquaSnap is a high power, ultra-sensitive formulation to deliver precise results for low levels of ATP. AquaSnap's chemistry is robust and resistant to harsh samples or sanitizer effects. 

Benefits

  • Ready-to-use out of box
  • Easy-to-use and reduces user variation
  • Patented design produces repeatable and accurate results
  • Tolerant to temperature abuse and sanitizers
  • All-in-one test device with collection dipper tip
  • Consistent sample collection (100 µl) over swab or sponge tip test
  • Liquid-stable chemistry eliminates the need to reconstitute a pellet, giving more accurate results with less variation
  • True and accurate results at low RLU levels
  • Reliable trending at low ATP and low RLU levels
  • Low carbon footprint - Recyclable #7

Specifications

  • Shelf life:
    • 15 months at refrigerated temperatures (2-8ºC)
    • 4 weeks room temperature (21-25ºC)
  • Compatible Luminometers

    • EnSURE™ Touch
    • EnSURE™
    • SystemSURE Plus
.
Maximum quantity available reached.